Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. Soc. Colomb. Oftalmol ; 47(1): 72-79, 2014. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-969273

ABSTRACT

Objetivo: evaluar los resultados visuales a 30 + 3 meses del implante binocular del lente intraocular Crystalens HDTM. Diseño: serie de casos. Métodos: en seis pacientes (12 ojos) con implante binocular del lente intraocular Crystalens HDTM se evaluó la agudeza visual no corregida (AVSC), la agudeza visual corregida (AVCC) en visión cercana (40 cm), intermedia (80cm) y lejana (4mts), amplitud de acomodación, test de sensibilidad al contraste, biomicroscopía y encuesta de satisfacción. Resultados: los 6 pacientes evaluados con edades de 62.5 + 16 años presentaron AVSC a 40 cm de +0.1 LogMAR a distancia intermedia de -0.1 LogMAR y a 4 mts fué de 0.0 LogMAR; la AVCC fué de +0.1 LogMAR a 40 cm, 0.0 LogMAR a 80cm y a 4m permaneció sin cambios (0.0 LogMAR). La amplitud de acomodación fué de 4.00 +/- 1.00 dioptrías (D), la sensibilidad al contraste disminuyó en condiciones mesópicas con glare. De los 6 pacientes, 3 (50%) requirieron capsulotomía Nd-YAG laser y sólo 2 (33%) de los pacientes refirieron presencia de halos y glare. Según la encuesta de satisfacción, 5 pacientes (83%) fueron capaces de realizar sus actividades cotidianas sin dificultad ni requerimiento de corrección. Conclusión: el lente intraocular acomodativo de una óptica Crystalens HDTM logra resultados visuales adecuados a distancia lejana e intermedia, requiriendo +0.65 D (rango +0.50 a +1.75) de adición para cerca. En condiciones mesópicas presenta bajo desempeño y presenta un alto porcentaje de opacidad de capsula posterior.


Purpose: to evaluate the visual outcomes of intraocular lens Crystalens HDTM after 30 months of binocular implantation. Design: case series. Methods: in 6 patients (12 eyes) with binocular implant of Crystalens HDTM, we assessed uncorrected (UVA) and corrected (CVA) visual acuity at near (40 cm), intermediate (80cm) and distance (4m), accommodative amplitude, contrast sensitivity, biomicroscopy and satisfaction survey. Results: age of six evaluated patients was 62.5 + 16 years, mean UCVA at 40 cm was +0.1 LogMAR, at intermediate was -0.1 LogMAR and distance VA was 0.0 LogMAR. Mean BSCVA was 0.0 LogMAR at 40 cm, 0.0 LogMAR at 80cm and remained unchanged at distance (0.0 LogMAR). The accommodative amplitude was 4.00 + / - 1.00 diopters, the contrast sensitivity was diminished under mesopic conditions with glare. Of the 6 patients, 4 (66%) patients required Nd-YAG laser capsulotomy and only 2 (33%) of the patients reported presence of halos and glare. Regarding satisfaction survey, 83% were able to perform daily activities without difficulty or correction requirement. Conclusions : the intraocular accommodative lens Crystalens HDTM, restores distance and intermediate vision requiring +0.65 D (range +0.50 to +1.75) at near distance. There is low vision quality under mesopic conditions and a high percentage of posterior capsule opacity.


Subject(s)
Lens Implantation, Intraocular , Presbyopia/surgery , Cataract Extraction , Multifocal Intraocular Lenses
SELECTION OF CITATIONS
SEARCH DETAIL